21-3601E rev1.3 xL Simplified Installation Guide 5
North American Modem
(Bell 103, 300 baud)
For Director Software Communications to Feature set 3
World Wide Modem (2400 baud)
For Director Software Communications to Feature set 7
CPU Failure available with main control module firmware 4.3 or
greater.
312 4
Seized Tip
Seized Ring
Tip
Ring
Off Hook
LED
Turns on when
unit dialing out.
Plugs into xL Main Control Board
Modem Expansion Socket
North American Modem
312 4
Seized Tip
Seized Ring
Tip
Ring
Off Hook LED
Turns on when
unit dialing out.
Plugs into xL Main Control Board
Modem Expansion Socket
World Wide Modem
756 8
0V
Line Failure
9312 4
Output 8
Output 7
Output 6
Output 5
Output 4
Output 3
Output 2
Output 1
To REDCARE Unit
01
1
2
3
2 vertical Jumpers in 1+2 = Output 8 will be 12VDC
high from 0V if main control board CPU fails
2 vertical Jumpers in 2+3 = Output 8 will be 0V low
from 12VDC high if main control board CPU fails
1 Jumper in 1+2 on left side =
Output 8 is a standard output #
8 on this board.
CPU
Failure
with
REDCARE
Interface
From REDCARE Unit
See “ENABLE LINE
FAILURE” this page.
NOTE: Bell 103 and World Wide Modems will call Director Software manually to their Feature Set limitations above. An external
modem must be used for Director communications above Feature set 7. An external modem connected to the main control module
can not call Director. See the previous Main Control Module detail. Director can call the main control module and maintain a “stay
connected” send and receive session using an external modem. Alarm reporting is not possible with an external modem. Alarm
reporting is only done with Bell 103 and WW Modems or IP to SIP.
Feature Expansion Board
Required for Access Control in any feature set.
Feature Expansion Board
Feature Expansion Socket
Plugs into xL Main Control Board
Memory Expansion Socket
WW Modem “CPU Failure” available with main control module firmware 4.3 or greater.
CPU Failure (WW Modem)
Output 8 must be programmed as “System Fault” in System Outputs. Use Director Software outputs or Simplified or Advanced
(B000:00, System Outputs #56) keypad programming. For a negative to positive output, it can be left defaulted. For a positive to
negative output, it must also be programmed to be inverted.
ENABLE LINE FAILURE on WW Modem
This feature is used to monitor for line faults from switched communicators such as Redcare
NOTE: The WW Modem must be plugged into the main control module.
Simplified Configurations:
Comms (Communications) Configure Group
– Enable Line Failure: Default: No
(UK ACPO = 9yes)
– Line Fail Polarity: Positive 12VDC going to Negative 0V or Negative 0V going to Positive 12VDC. Default: Positive
Advanced Configurations: S005È03
– Field 2: Parallel STU 8OP Supports Line Fail: 9(yes) (no) Default: no
(UK ACPO = 9yes)
– Field 3: Parallel STU 8OP Line Fail Negative Polarity: 9(yes) (no) Default: no = Positive Polarity