21-3601E rev1.3 xL Simplified Installation Guide 3
Main Control Module
NOTE: Any expansion modules used with the xL system, like the 8 and 16 Point Expanders, can also be used on the xL Main
Control Unit, Module Bus (SNAPP).
Mounting a Control Box
On Dry Wall Use 1/8” hollow wall, expansion anchors (p/n 331-8755). Unscrew the screws from the anchors. Hold the control box
on the mounting surface. Mark the mounting holes. Force a starter hole in each mark with a sharp tool e.g. a screw driver with a
small, flat edge. Hammer the anchors into each hole. Align the box mounting holes over the anchor holes and screw in the anchor
screws until tight.
On Concrete Surface
Hold the control box on the mounting surface. Mark the mounting holes. Use a hammer drill with a 3/16”
carballoy drill bit and make 1” deep holes in each marking. Insert a # 6-8 plastic anchor (p/n 331-8470) in each hole and hammer
them in. Use # 8 X 1”, Phillips, wood screws (p/n 738-2169) to screw into the plastic anchors and mount the box.
Control Box Dimensions (height, width, depth)
North American Main Control Unit 573-6801: H355mm x W254mm x D86mm (H14” x W10” x D3, 3/8”)
Main Control Unit with 230V transformer (European) and IPSU (intelligent power supply unit) Expander 573-2912:
H470mm x W305mm x D89mm (H18, ½” x W12” x D3, ½”)
Input Expander 573-4714
: H259mm x W203mm x D76mm (H10, 3/16” x W8, 1/8” x D3”)
MAIN CONTROLLER METAL ENCLOSURE
WITH 230 VOLT TRANSFORMER
573-2912
Main Control Board
Battery
cable plug
Position
battery with
terminals on
left
Battery bracket mounting holes for 17Ah
battery bracket 232-2606. Order kit 250-3617.
7Ah battery bracket 232-2605 from supplied
accessories kit. Mounted on 7Ah battery.
312
TB2TB1
312 312 312 12 312 312 312 312 312 312312
312 4 312 4
TB3TB4TB5TB6 TB7TB8TB9TB10TB11TB12
TB13
TB14
Spare fuse
Fuse in use
Fuse tray
Terminal block screw holes cover (353-2004).
230 Volt Transformer
Replacement fuse: ½ AMP
fast blow p/n 342-0005
Once electrical wiring is complete, obtain
cover from supplied accessories kit and
plug on fuse block screw hole assembly.
Fuse block (353-2003)
Electrical
Ground
Procedure for Cold Booting the Main Control Board and Clearing Memory
1. Remove all power from main control board.
2. Insert the Program Reset Jumpers (CFG0 and CFG1) horizontally. See Program Reset Jumpers on the right side of the main
control module in the “Main Control Module” diagram.
3. Apply AC Mains power.
4. The Status and Trouble LEDs will flash on and off together slowly.
5. Remove the 2 jumpers.
6. The same LEDs will momentarily flash rapidly together. (Controller processing)
7. The trouble light will turn off and only the Status LED will flash rapidly.
8. Proceed through the following “
Powering on the System for the First Time and Understanding How to Program the
System Using the LCD Keypad” section
.
9. The keypad will display regular screens and only the Status LED will flash slowly to indicate a normal condition.
10. The memory has been returned to factory defaults. Reconnect all power.