iv xL Simplified Installation Guide
21-3601E rev1.3
CE – Conformity
The xL System described in this manual conforms to the requirements of the Council Directive 89/336/EEC – The EMC Directive
and 73/23/EEC – The Low Voltage Directive. 1999/5/EC-The R&TTE Directive. To maintain compliancy with this directive, it is
essential to adhere to the installation recommendations described within this manual.
Standards to which Conformity is Declared:
• CISPR 11:2003 / EN55011:2003 – Class A – Limits and methods of measurements of radio disturbance characteristics for
industrial, scientific and medical (ISM) radio-frequency equipment.
• CISPR 22:2003 / EN55022:2003 Class A – Limits and methods of measurement of radio disturbance characteristics of
information technology equipment.
• EN 50130-4:1995 – Electromagnetic compatibility – product family standard: Immunity requirements for components of fire,
intruder and social alarm systems.
• EN 60950-1: 2001 – Safety of Information Technology
• TBR21:1998 – Terminal Equipment Attachment requirements for the connection to the analogue PSTN
Standard Description Severity Applied Performance
Criteria
IEC 1000-4-2
EN 61000-4-2
Electrostatic
Discharge
6kV Contact Discharge (direct and indirect)
8kV Air Discharge
A
A
IEC 1000-4-3
EN61000-4-3
ENV 50140/240
Radiated RF
Immunity
10V/m, 80-2000 MHz, 1 kHz 80% AM
modulation
10V/m 80-2000 MHz, Pulse Modulation with 1
Hz Square
A
A
IEC 1000-4-4
EN 61000-4-4
Electrical Fast
Transient
+/-2kV on AC lines
+/-1kV on DC & I/O lines
A
A
IEC 1000-4-5
EN 61000-4-5
Surge Withstand
Immunity
+/-2kV Common Mode on AC lines
+/- 1kV Differential Mode on AC Line
+/-2kV Common Mode on I/O lines.
A
A
A
IEC 1000-4-6
EN 61000-4-6
ENV 50141
Conducted RF
Immunity
10Vrms, 0.15-100 MHz, 1kHz 80% AM
modulation on AC lines
10Vrms, 0.15-100 MHz, 1kHz 80% AM
modulation on I/O lines
10Vrms, 0.15-100 MHz, Pulse Modulation with
1 Hz Square.
A
A
A
IEC 1000-4-11
EN61000-4-11
Dip
Dropouts
Voltage Variation
60% for 0.5, 1, 5 & 10 cycles repeated 3 times
every 10s
30% for 0.5, 1, 5 & 10 cycles repeated 3 times
every 10s
100% for 0.5, 1, 5 & 10 cycles repeated 3
times every 10s.
+10%, -15% for AC from nominal
A
A
A
A
IEC 1000-3-2
EN61000-3-2
Harmonic Current
Emissions
Class A (Other), Class B (Portable Equipment),
Class C (Lighting Equipment) or Class D
(Special Current Waveform)
PASS
IEC 1000-3-3
EN61000-3-3
Voltage
Fluctuation and
Flicker in Low-
Voltage Supply
Systems
Voltage Fluctuation
Flicker
PASS
PASS
Not verified by UL