-Panel:
If the tree is
not
set to show
items on a panel-by-panel basis, you
will be able to select a panel here (for
systems that have more than one).
A "Panel Group" reference may also be
shown here,
or
you can set the 'tree' to list
configuration topics separately for each
panel. For more information, refer to "Other
Desktop Choices".
On This Form
- Panel
(firmware) and
File Versions:
Revision information for the panel
(which is read-in during each communication
attempt);
To allow panel communications, the panel version
must be set correctly through the "Account
Information" screen.
Account Information: See the section entitled
"Account-Wide Panel Settings" (previous).
Panel Communications: See the section entitled
"Panel Communications and Updates" (previous).
Note:
Some features may be supported
only
after
upgrading to the latest firmware revision (typically to
match the software revision).
- Siren Time:
This is the duration for any siren
activations for the entire system/panel.
The Siren Feature: This pertains to monitored sensors
(input points), system/equipment conditions, and/or
panic/emergency keys that have been set to trigger a
siren condition—as signalled by a programmable
output set to activate on a system or area "siren"
condition.
Also see:
•
Equipment Settings (Pseudo / Internal Inputs)
•
Input Points—Monitored Sensors
Emergency keys: Pertains to 1st 3 inputs on an
LCD keypad.
•
Input Points—Pre-Defined Sensor Types
•
Input Points—Custom Point Types
•
Programmable Outputs (Signalling & Device-
Switching)
- AC Synchronization:
Frequency of AC source
to sync with for panel time display accuracy.
Note:
With an unstable AC service, select "No
Sync--AC Power Detection" (AC failure will be
reported if the frequency drops below 12.5 Hz);
- SNAPP Baud Rate:
This is the speed this main
panel communicates with the modules
connected to it.
The higher speed (38400) is recommended in all
systems (especially with door and/or elevator
controllers), and
required
with suite-security
keypads.
Note:
Trouble-free communications
requires proper (shielded) cabling, and adherence to
wiring guidelines covered in your system-
commissioning guide.
- System Message:
A greeting of up to 16
characters to appear at LCD displays (alternates
with the time, and alarm conditions).
- Input Point Fast Restore:
Whether or not a
point restoral (return to normal) is to be sent
within 1 minute (versus only at siren time-out);
- Ring Back Required on Arming:
Whether or
not the monitoring station will cause a keypad
tone and short siren squawk to confirm each
time an area is armed--as required for UL-listed
systems.
LCD Keypad Only
- Prompt for Entry Delay on LCD Keypad:
Whether or not the user will be asked if they
want the optional entry delay each time any area
is set to STAY. (An entry delay provides time
for an authorized entrant to disarm the area.)
-Arm/Disarm Local Area Only:
This limits a
system LCD keypad to allow arming and
disarming of only the area associated with the
keypad. (Otherwise, users can arm any area
as per their assigned authority).