500-9041 v4.1
Welcome Report Control Admin
Sys Config
Tech-Ref
207
Desecure
Cab Desecure Schedule
- Schedule:
This is a schedule to determine the
times when an access card will be required to
use the floor call-buttons.
To define a schedule, refer to "Schedules for User
Access and Area Automation".
- Mode:
Whether free access to floors is to be
provided inside or outside of schedule chosen
above (if applicable).
Communication Fail
-Fallback Mode:
Cards to be granted access if
the elevator controller module is unable to
communicate with the main MONITOR AFx
panel database:
•
None:
No cards/tokens accepted;
•
Valid Token Format:
All readable
cards/tokens accepted;
•
Valid Site Code:
All cards/tokens with the
correct site code will be granted access;
•
10 Fall-back Users:
Only the users who are
assigned as 'FallBack Users'. For details,
refer to "Fall-Back Users...".
- Desecure on Comms Fail:
Whether or not all
floor call-buttons are to be enabled whenever
the elevator controller or floor relay board has
lost communications.
- Relay Off When Desecure:
This sets the
normal physical state of the floor selection
relays.
= Relays normally powered (held open), and
powered down only when access to floors is allowed
(and during power failure);
= Relays normally de-energized (closed), and
energized only when access to floors is allowed. (No
floor access during power failure).
Wiring:
Relays will typically be wired differently
based on this setting:
Requires COM – N/
C
wiring;
Requires COM – N/
O
wiring.
Elevator controller floor selection relays must also be
wired to the floor call buttons in the same relative
order for
all
elevator (lift) cabs (such as from lowest to
highest accessed). The floors must then be entered in
the same order overall (such as from lowest to
highest). To set up floors, refer to the floor
configuration topic.